124 - Stop Data

The stop data command is intended to be used when the number of good data points ( good SEM data points ) exceeds some number of observations. The 124 command is group specific and should follow the 103 command within a group. When the number of observations requested is reached a comment will be placed in the ATIS output file.

IDENTIFIER: 124

INFORMATION

Name Type Input Output
1 Group number Integer Required Required
2 Number of good (SEM)

Observations to stop taking data

Integer Required Required
3 Number of total observations to stop taking data Integer Required Required

Example
124
303 100 500

Where

1. Group Number: is the group number from the 103 command

2. Number of good SEM observations: to stop taking data. If this number is zero the stop point will revert to the total number of observations

3. Number of total observations: to stop taking data. If this number is zero control will revert to the number of good SEM observations.